Skip to content
ProleanTech Get a Quote →

Machining standards & quality control

Quality & Standards

Machining standards & quality control

Every Prolean order is machined and inspected against a documented standard. This page sets out the tolerances we apply by default, the tighter limits we can reach on a specified feature, what is checked on every batch, and which reports ship with the parts.

All uploads are secure and confidential.
Prolean quality inspection room with a coordinate measuring machine, optical measuring system and granite surface plate
ISO 9001:2015 Certified by SGS United Kingdom Ltd
ISO 2768-fH / mK
Our default class when a drawing has no tolerance call-out — stated on the inspection record
± 0.0002 in
≈ ± 0.005 mm — on a specified feature, subject to engineering review and confirmed at quote
ISO 2859-1 · Level II
Sampling applied to production batches — code letter, sample size and Ac/Re stated on the inspection record
7 optional documents
A packing list ships as standard — everything else is requested at quote stage
01 Standards

Four published standards cover almost every order

If your drawing calls out something different, we follow your drawing. Where it is silent, these are the defaults we apply.

01

ISO 9001:2015 — quality management system

Certified by SGS United Kingdom Ltd and independently audited, so the process behind your parts is documented and externally checkable — not just claimed.

See the certificate and how to verify it
02

ISO 2768 — general tolerances

The class letters carry two different things. f and m are the linear and angular classes of ISO 2768-1:1989 — f is fine, m is medium. H and K are the geometrical classes of ISO 2768-2:1989, which was withdrawn in February 2021 and replaced for new drawings by ISO 22081:2021.

fH for metals and mK for plastics is Prolean's own agreed default, not something ISO fixes by material. Drawings still marked mK stay binding and we read them the same way — but we do not present the withdrawn part as a current general rule, and we do not silently re-map H and K to ISO 22081. If your drawing names its own class, the drawing wins.

How the ISO 2768 classes work ISO 22081:2021 on iso.org
03

ISO 965-1 — metric thread tolerance

Thread tolerance class for metric threads. Where your drawing does not name one we apply the medium class, and we state which class was used on the inspection record.

Thread and knurling defaults
04

ISO 2859-1 — acceptance sampling

ISO 2859-1:1999, General Inspection Level II, single sampling, normal inspection, applied to production batches. Severity is graded critical, major or minor against a documented defect book, and the plan's code letter, sample size and acceptance number are stated on the inspection record.

AQL levels and defect classes
02 Tolerances
± 0.0002 in
± 0.005 mm

Our tightest achievable limit — on a specified feature, after engineering review. A capability ceiling, not a default for your drawing.

CoarseMediumFine
General tolerance — metal (drawing silent) ISO 2768-fH — Prolean default
General tolerance — plastic (drawing silent) ISO 2768-mK — Prolean default
Tightest achievable — specified feature ≈ ± 0.005 mm (± 0.0002 in), after review
Minimum feature size 0.5 mm or Ø 0.50 mm
Minimum wall thickness 0.8 mm metals / 1.5 mm plastics

The achievable limit is not one number for every feature — it depends on the material, the feature size and geometry, the machining process, and the surface finish state. Send the drawing with the requirement called out and our engineers confirm feasibility before quoting: the tolerance we commit to is the one on your quote. See the full CNC machining capability list.

Two different numbers. The general tolerance applies when your drawing is silent; the achievable limit applies only to a feature that is called out and reviewed. Both are capability references — the tolerance, inspection method and report for a specific part are confirmed on the quote for that part.
03 Threads & knurling

Thread call-outs are the most common thing missing from a drawing

If yours has one we follow it. If it does not, we apply the defaults below — and we tell you which default we used on the inspection report.

For metric threads we default to ISO 965-1 medium class. For UNC and UNF without a call-out we apply ASME B1.1-2003 — 2A external and 2B internal. ACME and Thor-labs threads we do not accept.

Default thread tolerance class
Thread sizeInternalExternal
Threads up to M1.45H6h
Threads M1.6 and larger6H6g
Knurling — DIN 82 / ISO 13444:2012 by default. Mark the knurl position on the drawing. A different knurling standard can be raised at quote stage and we confirm feasibility before manufacture.
Prolean inspection process: a machined part being checked against the drawing call-out
04 Surface finish

Finish is guaranteed by examination under fixed conditions, not by assumption

The same viewing setup is used on every batch — that is what keeps batch 1 and batch 10 looking the same when they reach your line.

Viewing distance
50 ± 10 cm
with corrected vision
Viewing angle
45°
across all directions
Illumination
500–1000 lux
neutral white

Cosmetic — a consistent surface with no visible flaw on the primary face. Non-cosmetic — minor visual blemishes are permissible because appearance is not functional. Tell us which one your part needs. See all surface finish options.

05 Equipment

Every dimensional check happens in our own quality room

Dimensional inspection runs in our own quality room, on the same floor as the machines that cut your parts. Where a specification calls for external testing — material chemistry, for example — we use an accredited third-party lab and say so on the report.

Primary Coordinate measuring machine in the Prolean quality room, granite table and probe head

Coordinate measuring machine

Programmed 3D measurement of critical dimensions, position and profile. Reports are generated from the measuring program rather than typed by hand, so the numbers on your dimensional report are repeatable run to run.